SU-8 Shrinkage
Goal: Measure SU-8 shrinkage that have gone through various soft and hard bake conditions
To measure the shrinkage, the SU-8 scaffolds needed to be lifted off, but there was some issues. Originally, the SU-8 was spincoated onto an oxide layer, which would be etched away using BOE. The SU-8 had appeared to be disintegrating due to the long exposure time to BOE. I switched over to the XeF2 which was safer for the SU-8. I was able to lift off six of the eight conditions. The ones that I could not lift off are 65° C 10 min/ 125° C 2.5 min/ 200° C 2.5 min and 65° C 10 min/ 125° C 2.5 min/ 120° C 2.5 min. The 65° C 10 min/ 95° C 2.5 min/ 200° C 2.5 min and 65° C 10 min/ 95° C 2.5 min/ 120° C 2.5 min was hard to liftoff.
I measured the width and height of the liftoff scaffolds and compared it to the scaffolds on the wafers.
| Condition | Scaffold | Wafer | ||||
| Width (µm) | Height (µm) | Width (µm) | Height (µm) | Width Strain % | Height Strain % | |
| 65° C 1 min/ 125° C 2.5 min/ 200° C 2.5 min | 221 | 110.5 | 223 | 111 | 0.90 | 0.45 |
| 65° C 1 min/ 125° C 2.5 min/ 120° C 2.5 min | 221 | 110.5 | 223 | 111 | 0.90 | 0.45 |
| 65° C 10 min/ 125° C 2.5 min/ 200° C 2.5 min | N/A | N/A | 222 | 111 | ||
| 65° C 10 min/ 125° C 2.5 min/ 120° C 2.5 min | N/A | N/A | 222 | 112 | ||
| 65° C 1 min/ 95° C 2.5 min/ 200° C 2.5 min | 223 | 111 | 223 | 111 | 0 | 0 |
| 65° C 1 min/ 95° C 2.5 min/ 120° C 2.5 min | 222 | 110.5 | 222 | 111 | 0 | 0.45 |
| 65° C 10 min/ 95° C 2.5 min/ 200° C 2.5 min | 222 | 111 | 222 | 111 | 0 | 0 |
| 65° C 10 min/ 95° C 2.5 min/ 120° C 2.5 min | 222 | 111 | 222 | 111 | 0 | 0 |