• UV-ozone follow up

    So I think I have confirmed that PDMS is at least one of if not the major contributor to the contact angle problems in the UV-ozone system. Control image before any treatment: I then dried the chip and placed it in the UV-ozone system with two slides that each had two strips of PDMS. Since…

  • Separation Repeats

    I wanted to have 3 repeats of the previous salt-tuned separations.  I’ve gone through and performed the densitometry on a couple more gels and compiled the results. 100mM: The first two experiments were from the two experiments set up on the same day.  The third (yellow triangle) was set up a different day and does…

  • TEER and Pinholes

    One of Christine’s projects was to determine if pinholes affected electrical resistance (TEER) measurements.  She summarized her work here.  I collected her data and did some negative controls to finish this work up.  Here’s the graph: The “no membranes” data is from Sepcon transwells with pnc-Si chips but without membranes (I broke them before assembling…

  • New Gold Ladder

    UPDATED: More sizing characterization (see chart and figure below). We recently purchased our own gold ladder, and today I’ve done some of the initial characterization.  Particles come in 5, 10, 15, 20, 30, and 40nm.  Here are the absorbance scans in both water and 10mM KCl: The scans look similar, so none of these particles…

  • Long-term Discoloration

    Anant and I have been doing long-term discoloration experiments for the past few weeks.  We set up samples in “ideal” conditions – pnc-Si in transwells with pnc-Si side down, autoclaved samples and in the incubator (lower OH-).  The only non-ideal component is the use of DMEM+10%FBS with high NaHCO3 (3.7 mg/mL).  Chips were RTP’ed at…