Here, I will post figure drafts for the paper that introduces the modular µSiM (m-µSiM).
Figures
Fig. 1. m-µSiM Assembly. (A) Fixtures are used to guide components and membrane together. Component 1 is composed of an acrylic top layer with a TranswellTM-style open well and a PSA sealing layer. Component 2 is composed of a thin, PSA bottom channel and COP imaging layer. (B) Assembly is a two-step process. Step 1: Bond component 1 and membrane. Place membrane on fixture A1 pedestal. Place component 1 face down over membrane. Use fixture A2 to press firmly and activate PSA. This irreversibly bonds membrane to component 1. Step 2: Bond components 1 and 2. Place component 2 in fixture B1, channel-side up. Place component 1 with membrane onto component 2. Use fixture B2 to press firmly to activate PSA, irreversibly bonding component 1 and component 2. (C) The modular assembly allows different style membranes to readily be selected for the application at hand. Component 1’s open well format allows easy cell culture, and access ports provide access to the bottom channel. They are designed to seal-to-fit standard P20 and P200 pipet tips.Fig. 2. in situ permeability assay optimization on cell-free devices. (A) A confocal microscope is focused 133 µm below the membrane, within the chip’s trench. Dye diffuses from the well into the trench (left). Example of corresponding image (right) highlights region of interest, where 1-D diffusion occurs and fluorescence measurements are taken (yellow line). (B) Diffusion coefficients can be solved using a Fick’s Law-derived equation, modeling 1-D diffusion. This equation assumes there is no widening of trench walls with this model. (C) Dye can be seen diffusing into the trench over the course of ten minutes. Images are of 10 kDa Dextran-AF488 diffusing across a blank NPSN membrane chip. (D) Example plots of diffusion across uncoated and coated chips using 10 kDa Dextran-AF488 (top) and lucifer yellow (LY, bottom). The analytical solutions fit well the the experimental data. The resulting diffusion coefficient from the analytical solutions for 10 kDa Dex-AF488 across an uncoated membrane are in statistical agreement with the literature. Coating the membrane significantly decreases the apparent diffusion coefficient, whereas larger apparent diffusion coefficients are measured with smaller molecules. N = 3 per group. Students t-test, p < 0.05.Fig. 3. in situ permeability assay optimization using hCMEC/D3. (A) A confocal microscope is focused 133 µm below the membrane, within the chip’s trench. Dye diffuses from the well, across an endothelial cell layer, and into the trench (left). (B) Permeability can be solved using a constant flux model. (C) Example plots of the analytical solutions for permeability of 10 kDa Dex-FITC (top) and lucifer yellow (bottom) across an hCMEC/D3 monolayer using the free diffusion coefficient. The analytical solutions fit well the the experimental data.Fig. 4. Sampling permeability assay optimization and validation of assays. (A) Sampling method process for collecting dye from the channel. A reservoir is added to one port that access the channel, and another pipet is used to pull media across. Media withdrawn is added to a well plate for fluorescence measurements. (B) COMSOL was used to model the sampling process across coated-control devices (B) and cell-seeded devices (C). HOWARD BRIEF SENTENCE OF MODEL FOR DIFFUSION. (D) COMSOL model sampling efficiency of lucifer yellow for different volumes extracted from the channel. Sampling using a single 50 µl draw clears dye from the channel for both coated-control and cell-seeded devices. (E) hCMEC/D3 permeability to 10 kDa Dextran and luficer yellow experimentally determined using the in situ and sampling methods. The in situ method includes analysis using both the free diffusion coefficient and measured diffusion coefficient through coated-membranes. Permeability values found in the literature are included. N = 4-6 per group. Two-way ANOVA, p < 0.05.Fig. 5. Validation of m-µSiM distribution to non-engineering labs and replicability of data utilizing EECM-BMEC-like cell differentiation protocol. (A) EECM-BMEC-like cells express similar patterns of key junctional molecules when derived and cultured on m-µSiM devices at UR and UniBe. (B) EECM-BMEC-like cells upregulate expression of cell adhesion molecules upon exposure proinflammatory stimuli in a comparable manner when derived and cultured on m-µSiM devices at UR and UniBe.
Remaining data to obtain: Occludin staining in IMR90-4 from UniBe in µSiM. We have tried this after 2 day culture in µSiM, which worked at UR but is not working at UniBe.
Current problem: Occludin is not seen in junctions but in cytosol.
Solution A: Test longer culture time to give junctions time to mature.
Solution B: Use ReDup or do not show reproducibility for occludin in figure. Note difference in Supplement.
Fig. 6. EECM-BMEC baseline permeability and response to TNFa+IFNg treatment. EECM-BMEC-like cells demonstrate comparable baseline permeabilities between lab. Cells increase permeability in response to proinflammatory stimuli in a comparable manner when derived and cultured on m-µSiM devices at UR and UniBe.
Remaining data to obtain: Sampling permeability data of IMR90-4 from UniBe in µSiM. We have tried this after 2 day culture in µSiM, which worked at UR but is giving high baseline permeability at UniBe.
Current problem: Baseline permeability is too high at UniBe in µSiM and no response to cytokines. Same cells in transwells are fine.
Solution A: Test longer culture time to give junctions time to mature. Hopefully this will improve baseline permeability and we will now see response to cytokines.
Solution B: Use ReDup or HUVEC to show success of permeability assay in a non-engineering lab.
Fig. 7. Modularity of m-µSiM is demonstrated in immune cell transmigration studies. (A) Neutrophil migration across EECM-BMEC-like cells. While migration using both NPN and hybrid membranes can be analyzed by video tracking, only neutrophils migrating across hybrid membranes can enter the bottom channel and be collected for further analysis. (B) Statement about Bern T cell migration.
At UR, we need to repeat with Dan’s optimized methods. The EECM-BMECs recede in videos for NPN.
At UniBe, we see about 3% migration of T cells into channel after 2 hrs on non-stimulated EECM-BMECs. Transwells usually have about 10% migration but higher micropore densities. We have several example images of remaining adhered T cells. We would need to repeat 0.625% micropore density if we want to include both since two chips broke in preliminary experiment. We could also cut 0.625% and just show we see nothing across NPSN.
Since the basic protein diffusion experiments went well, I’m moving up to something that more closely resembles an actual assay application. The basic idea is this: Biotin-conjugate FLAG antibody will be bound to Avidin acrylic beads in order to make them far too large to pass through the MP8NP50 membrane. Then, Bacterial Alkaline Phosphatase (bAP)…
Discoloration Assays Introduction: pnc-Si chips were monitored for discoloration to find chips that had not been previously RTP’d. These assays were necessary in order to find chips that could potentially be used for cell proliferation assays later. Setup: pnc-Si chips were autoclaved and placed in a 24-welled plate with 300uL of DMEM and incubated at…
I ran new experiments over the weekend in which I tested NaCl at 10, 25, 60, and 155mM. I also ran filtrations in the presence of 10mM LiCl and 10mM CsCl. These experiments were performed with chips from wafer # 024. I am only providing the Filtrate / Retentate ratios. It is obvious that the…
Today I tried to pass 5 nm gold through three different membranes with similar cut-offs but distinct mean diameters and porosities. All the samples I used were ozoned yesterday and tested for water permeability. Based on the absorbance measurements, it seems that the 5 nm Au passes through 582 and 558 but not the carbonized…
Last week I took a series of TEM images from all but one position on wafer 638. Below are the TEMs, histograms, and porosities vs. distance from center plots. “Xpos”, “xneg”, “ypos”, “yneg” indicate which axis the images were taken from. Positive x-axis Negative x-axis Positive y-axis Negative y-axis Wafer 638 porosity vs. position While…
This is part of our work studying how cells adhere, spread and proliferate on varying pore size/porosity SiO2 membranes. This post will be a qualitative look at how HUVEC spread over membranes by staining for actin filaments. In a future post we will quantify the degree of spreading at 1hr, 4hrs and 24 hrs. Calculation…