Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    Vapor based PEG deposition

    ByTejas Khire February 5, 2013

    This paper talks about PEG monolayer deposition using CVD. Here is the link for Ultrathin Poly(ethylene glycol) Monolayers Formed by Chemical Vapor Deposition on Silicon Substrates  

    Read More Vapor based PEG depositionContinue

  • NRG

    Hemodialysis update – Feb. 2013

    ByJim February 5, 2013

    Here is an aggregate of the recent posts/data on the Hemodialysis Project … Device Design/Demo Design idea for assembling multiple chips Gasket design for counter flow dialysis chip Peclet chip demo – > Dialysis Membrane modifications to prevent protein binding (HD PEG) Protein binding is reduced by both Adarza and Shestopolov treatments Damage of pnc-Si by…

    Read More Hemodialysis update – Feb. 2013Continue

  • NRG

    shear stress reduction via pnc-Si: analytical solution REVISITED

    ByHenry February 4, 2013July 7, 2014

    Hi all, A while back (in the link below) I have posted the analytical solution that allows us to solve the flow rate distribution in our shear-free system. shear stress reduction via pnc-Si: analytical solution However we do not have a closed-form solution at that time. After a brief discussion we believe that there should…

    Read More shear stress reduction via pnc-Si: analytical solution REVISITEDContinue

  • NRG

    Long Term Urea Clearance in Serum

    ByDean Johnson February 4, 2013

    I made 50 mL of 30% fetal bovine serum (FBS), 70% PBS, 0.5 mM urea. Pumped with syringe pump at 5.6 µL/min through an untreated and EA treated single slot dialysis chips in a stirred beaker of PBS (two separate experiments). We expect  (without Serum) a 30% extraction so from 0.5 mM urea to 0.35…

    Read More Long Term Urea Clearance in SerumContinue

  • NRG

    Paper for Review: Nanoporous Parylene for Ultrafiltration

    ByDean Johnson January 31, 2013

    If you know me at all, you know I enjoy nothing more than ultrafiltration and Parylene-C deposition. Now these activities are combined into one device to improve the biocompatibility (platelet activation and adhesion) of nanoporous membranes. In this letter, polyethersulfone (PES) membranes were coated with Parylene-C, poly(chloro-para-xylylene) aka (PCPX), while glycerin vapors rising through the…

    Read More Paper for Review: Nanoporous Parylene for UltrafiltrationContinue

  • NRG

    Pores in 60 nm pnc-Si

    ByJosh Winans January 31, 2013January 23, 2014

    We deposited a 20/60/20 nm OSO stack for an ellipsometry test.  We decided to try annealing the un-patterned wafer in the RTP at 1050 C with no susceptor with a 100 C/s ramp for 60 s. The attached SEM images show pores forming.  With these encouraging results, we are considering depositing 40, 50 and 60…

    Read More Pores in 60 nm pnc-SiContinue

  • NRG

    Updates about PEG treatment

    ByTejas Khire January 30, 2013

    In collaboration with Alex Shestopalov’s lab, I started working on liquid based PEG treatment on windowed sepcon chips. The treatment is a 3-day long protocol and involves multiple washing and drying steps with different reagents. Most of our sepcon chips broke down in first few steps itself. The initial wash consists of Nanostrip (sulfuric plus nitric…

    Read More Updates about PEG treatmentContinue

  • NRG

    Serum adsorption, detection, TRITC, TECAN, Fluorecence 'Scope

    ByDean Johnson January 19, 2013

      These Adarza chips were pre wetted with PBS then incubated with fetal bovine serum (FBS) overnight in the refrigerator then rinsed. TRITC (2 mg/mL) added to  chips and incubated at room temperature for one hour. Then rinsed once with reaction buffer then rinsed thoroughly with distilled de-ionized (DDI) water. I first measured using the…

    Read More Serum adsorption, detection, TRITC, TECAN, Fluorecence 'ScopeContinue

  • NRG

    Burst Pressure

    ByMohammad Musleh January 16, 2013

    Josh and I are taking a closer look at how the samples burst and what different factors can affect the strength of the membrane. We are specifically looking at minimum dimension, area, and perimeter. A wafer was designed that contained different sized samples. One of the three factors were held constant while the other two…

    Read More Burst PressureContinue

  • NRG

    10 and 15nm Cutoff Sepcons Both Allow Cytochrome C to Pass, but not BSA

    ByKarl Smith January 16, 2013

    In a previous post, we showed that both Cytochrome C and BSA at concentrations of ~1mg/mL through 20nm cutoff Sepcons with about the same filtrate concentration (~60% of the feed concentration). Yesterday (1/14/13) we repeated these experiments with 10 and 15nm cutoff Sepcons and demonstrated pretty clearly that either 10 or 15nm Sepcons can be used…

    Read More 10 and 15nm Cutoff Sepcons Both Allow Cytochrome C to Pass, but not BSAContinue

Page navigation

Previous PagePrevious 1 … 127 128 129 130 131 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore