• AFM retry

    I posted some pictures yesterday from AFM last week.  I got back onto the AFM today and re-scanned the megasonics cleaned virginia semiconductor wafers.  For each image, the top and bottom panels are the height and ZSensor scans, respectively.  All scans are 10um x 10um.  I did a linear analysis of the ZSensor data for…

  • 8 hour diffusion

    Because of the recent discoloration problems I observed with 24 hour diffusion using w670 and 673, I decided to try a shorter time point. 673 had a couple more samples to spare, so I tried an 8 hour diffusion experiment.  No discoloration was observed: This is the normal color of the wafer.  Slits were not…

  • AFM – Megasonics

    I got some wafers from Chris last week(?) that had undergone different Megasonics cleaning treatments by the manufacturer.  We’re trying to figure out if these treatments are actually cleaning the wafers.  I’ve been having trouble getting the AFM to stay in the “right” mode for imaging with these wafers.  However, I have gotten some images….

  • Water Permeability Statistics

    I’ve processed all the images used in the water permeability studies and found the following statistics from these images: Mean Diameter Mean Area Median Diameter Median Area Porosity Area Weighted Diameter 90th percentile Diameter I calculated the theoretical water permeability for each sample we’ve used and compared that to the experimental permeability using these statistics…

  • Original Contact Angle Study

    This is the original contact angle study performed using the DeLouise Lab’s Rame-Hart contact angle measurement tool.   The entire study was performed on 8/1/06-8/10/06. Observations: Contact angles of non-plasma oxidized samples start ~60 degrees and increase over about 10 hrs to ~75 degrees. Keeping the samples in diH2O halts this gradual increase. Plasma oxidized samples…

  • Material changes

    There’s been a flurry of activity regarding Jess’ recent discoloration post.  Specifically, there is a discussion about the recent materials changes that have taken place due to the rebuilt CVC sputterer.  This post is meant to supplement the ongoing materials discussion.  I have noticed that films deposited post-rebuild seem to have less background texture and…