Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    More Negative Data for the Nanofluidic Transistor

    ByKarl Smith April 19, 2016April 21, 2016

    I don’t think I ever posted it on the blog, but two years ago I discovered something neat. At the time, I was trying to make my nanofluidic transistor, and I was reading Marina’s thesis. She tried to improve the efficiency of our EO pumps by putting silver films directly on the front and back…

    Read More More Negative Data for the Nanofluidic TransistorContinue

  • NRG

    Ultrasound Generation via NPN Still Doesn’t Work, Even in Low Salt

    ByKarl Smith April 19, 2016April 23, 2016

    Two years ago (blog post), I asked Professor McAleavey to help me see if we could use NPN chips to generate ultrasound. I’d found a paper (An exact solution of AC electro-kinetic-driven flow in a circular micro-channel) that suggested, given the geometry of our chips, that if the chips could be used to generate sound, they’d…

    Read More Ultrasound Generation via NPN Still Doesn’t Work, Even in Low SaltContinue

  • NRG

    Proof of Concept for a AC Electro-Osmotic Mixer on an NPN chip

    ByKarl Smith April 15, 2016April 21, 2016

    I’ve been trying to make the following device work for the past few years: The people who have been studying this have been trying to use the phenomena to mix solutions, or using arrays of mismatched electrodes to generate a sort of conveyor belt pumping mechanism: My idea is to use the electrokinetic phenomena of AC…

    Read More Proof of Concept for a AC Electro-Osmotic Mixer on an NPN chipContinue

  • NRG

    Contact area dictates early cell-substrate interaction for endothelial cells on porous membranes

    ByAna April 13, 2016

    Abstract Endothelial cell attachment to porous substrates via focal adhesions is initially affected by pore spacing and not absolute porosity. Maturation of endothelial monolayers via cell-cell interactions occurred over the same time course regardless of substrate porosity, pore size and contact area. Cell-matrix interactions at maturity were dictated by substrate stiffness. Data       [missing figure] Fig. 4 Endothelial…

    Read More Contact area dictates early cell-substrate interaction for endothelial cells on porous membranesContinue

  • NRG

    Frequency modeling of Ussing chamber (standard) and iBidi chamber

    ByGreg Madejski April 9, 2016

    We desire to test the electrical perfomance of our membranes in the iBidi chamber. For comparison, I am using a gold standard Ussing chamber format to examine the contribution of our membranes to the overall frequency response of a system. I am using both a matlab model and a web-simulator (www.circuitlab.com) to examine an equivalent circuit model…

    Read More Frequency modeling of Ussing chamber (standard) and iBidi chamberContinue

  • NRG

    Neutrophil-endothelial transmigration through ECM gel scaffolded on microporous silicon nitride membrane

    ByTejas Khire March 28, 2016

    I have been working on developing a microvessel mimetic using our silicon membranes. Just as a recap of vascular biology, the basic components of a microvessel are endothelial cells, the basement membrane secreted by them (presence of perciytes is a plus), and extracellular matrix (ECM) on the abluminal side. This ECM is predominantly composed of…

    Read More Neutrophil-endothelial transmigration through ECM gel scaffolded on microporous silicon nitride membraneContinue

  • NRG

    Journal Club – Oo et al, 2016 – A nanoporous gold membrane for sensing applications

    ByGreg Madejski March 28, 2016

    Paper: Oo2016 Supplementary Info:Oo2016SI Abstract:  Design and fabrication of three-dimensionally structured, gold membranes containing hexagonally close-packed microcavities with nanopores in the base, are described. Our aim is to create a nanoporous structure with localized enhancement of the fluorescence or Raman scattering at, and in the nanopore when excited with light of approximately 600 nm, with a view…

    Read More Journal Club – Oo et al, 2016 – A nanoporous gold membrane for sensing applicationsContinue

  • NRG

    Dialysis Clearance GUI

    ByTucker Burgin March 23, 2016March 31, 2016

    I have just completed testing and documentation of a MATLAB GUI designed to allow anyone to make predictions of the clearance behavior of solutes though our membranes in tangential flow. I’m uploading the file here, which includes all the MATLAB code for the GUI, dependancies, and documentation. It will also appear under the resources tab on the…

    Read More Dialysis Clearance GUIContinue

  • NRG

    Journal Club: Fissell Dialysis Papers

    ByTucker Burgin March 21, 2016March 22, 2016

    “Preliminary Diffusive Clearance of Silicon Nanopore Membranes in a Parallel Plate Configuration for Renal Replacement Therapy” – Link “First Implantation of Silicon Nanopore Membrane Hemofilters” – Link My slideshow – Fissell Journal Club Slides These are two references for permeability and selectivity. Neither shows actual permeability or selectivity. Fissell(Roy)JMS10 Kahnani(Zydney)JMS09 Here is the chemical PEG modification paper…

    Read More Journal Club: Fissell Dialysis PapersContinue

  • NRG

    Silicon Ideal to Culture Patient-On-a-Chip | Insight & Intelligence™ | GEN

    ByJim March 21, 2016March 22, 2016

    http://www.genengnews.com/insight-and-intelligence/silicon-ideal-to-culture-patient-on-a-chip/77900627/ Organs-on-Chips Remotely Monitored, Controlled via Google Glass

    Read More Silicon Ideal to Culture Patient-On-a-Chip | Insight & Intelligence™ | GENContinue

Page navigation

Previous PagePrevious 1 … 68 69 70 71 72 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore