Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    Urea/f-BSA/cytochrome c concentrations in retentate after dialysis: 12 hours

    ByDean Johnson August 5, 2013February 13, 2014

    Continuing on the path of hemodialysis, we are increasing the complexity of the fluid being dialyzed. In this long-term experiment I will pump 100% serum with added urea (1mM) cytochrome c (1 mg/mL) and fluorescent BSA (1 mg/mL). So I need to detect urea, BSA, and cytochrome c in serum. Cytochrome c absorbs at 405…

    Read More Urea/f-BSA/cytochrome c concentrations in retentate after dialysis: 12 hoursContinue

  • NRG

    PDMS Coating Issues

    ByTucker Burgin August 5, 2013

    I’ve performed what might be the last test of the n-Dodecyl β-D-Maltoside (“DDM”) coating. This time I washed for three minutes each sample in HBS just like in the reference, used precisely the same concentration (and type, for that matter) of protein that was used in the reference, and tested a positive control, a negative control,…

    Read More PDMS Coating IssuesContinue

  • NRG

    AFM Scans of Coated, Annealed TEM Windows

    ByGreg Madejski August 2, 2013

    AFM images report Protocol: pnc-Si TEM  grids were mounted on thin silicone inserts. Surface treatments were applied to the grids. Except for the CellTak treatment, the treatments were all diluted in Hank’s Balanced Salt Solution (HBSS) and incubated with grids  for 2 hours and then washed off with PBS. CellTak was diluted in 0.1 M…

    Read More AFM Scans of Coated, Annealed TEM WindowsContinue

  • NRG

    3D Printing for Milli/Microfluidics

    ByGreg Madejski August 2, 2013

    I’ve been using a Makerbot 2 for the last week or so, trying to see if we can use the same PDMS contact lithography techniques that we are all familiar with. In short, yes, but there is plenty of work to be done to make it a robust process for microfluidics.   Makerbot Printer The…

    Read More 3D Printing for Milli/MicrofluidicsContinue

  • NRG

    Take Two: n-Dodecyl β-D-Maltoside Coating on PDMS

    ByTucker Burgin August 1, 2013

    Now that I’ve got plenty of fluorescent protein, I’ve moved back to testing protein adsorption to various surfaces. I’ve repeated the n-Dodecyl β-D-Maltoside (“DDM”) coating procedure (reference) with the goal of preventing or heavily decreasing the protein adsorption to the PDMS surface. This time I had a total of four samples: DDM treated, sham treated, untreated,…

    Read More Take Two: n-Dodecyl β-D-Maltoside Coating on PDMSContinue

  • NRG

    PEG Structures with Masks from Laser Printer

    ByKelly McNabb July 30, 2013

    The overall goal was to see is if it was possible to create a reliable low resolution mask that can be used for crosslinking PEG structures using a laser printer and transparencies sheets. With these masks, I explored to see if there is an effect on the PEG structures when dimensions such as the spacings…

    Read More PEG Structures with Masks from Laser PrinterContinue

  • NRG

    Single-Well CytoVus w/ SiO2 Membrane – Comparisons

    ByZachary Oppito July 29, 2013

    I’ve run a few comparative studies with the CytoVu devices that have SiO2 membranes in them.  From a previous NRG discussion, here is the comparison of a single location with only the fluorescent images, and that same location but with phase included: In the phase image, the pores can be seen through the cells, especially evident in…

    Read More Single-Well CytoVus w/ SiO2 Membrane – ComparisonsContinue

  • NRG

    For real this time: BSA-TRITC conjugation procedure works!

    ByTucker Burgin July 26, 2013

    I made this post last week concerning testing this procedure to make sure that the resulting solution is in fact fluorescent BSA and not just a mixture of free BSA and free TRITC. Unfortunately, I exercised my right as a rookie to make silly mistakes and confused 5-TMRIA for 5-TRITC! The two particles are very similar…

    Read More For real this time: BSA-TRITC conjugation procedure works!Continue

  • NRG

    Changes in hydrophilicity of EA treated pncSi after storage in water

    ByTejas Khire July 25, 2013

    In my previous post, I mentioned that the EA treated chips showed decreasing contact angles after their storage in water in contrast to gel-pack or vacuum container. However the EA treatment was 4 days old, and I lacked adequate controls. So this time, I chose smaller time durations to understand if this phenomenon can be…

    Read More Changes in hydrophilicity of EA treated pncSi after storage in waterContinue

  • NRG

    Procedure for labeling BSA with TRITC works

    ByTucker Burgin July 19, 2013

    IMPORTANT: I made a mistake, and mistook what was actually Tetramethylrhodamine-5-Iodoacetamide Dihydroidiode (5-TMRIA) for TRITC. 5-TMRIA is another Rhodamine derivative and has similar chemical properties to TRITC, but does not bind to proteins in the same way. The procedure should still work for conjugating TRITC with BSA (in fact, it should work even better,) but…

    Read More Procedure for labeling BSA with TRITC worksContinue

Page navigation

Previous PagePrevious 1 … 113 114 115 116 117 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore