Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    Adventures in Bioprinting

    ByStephanie Casillo February 3, 2016March 3, 2016

    Objective Develop an easily mainpulated reproducible vasculogenesis assay using hydrogels laden with endothelial cells (‘bio-ink’) patterned using the technique of extrusion bioprinting Bio-inks Develop a bio-ink with the following characteristics Cell viable: bio-ink must sustain cell life, allowing cells to manipulate and move through the hydrogel Vasculogenic: bio-ink must encourage (or at least not negatively affect) tubule formation…

    Read More Adventures in BioprintingContinue

  • NRG

    iBidi Microfluidic Integration Progress

    ByGreg Madejski February 2, 2016February 6, 2016

    As part of my work over at the University of Nottingham, I’ve been using iBidi devices to grow cells. Eventually, I will use their product to do Raman studies of cells grown on my MgF2 substrates. I’ve been making some progress towards that end using PDMS (I’ve been using 10:1 base to curing agent for…

    Read More iBidi Microfluidic Integration ProgressContinue

  • NRG

    Exosome Isolation Using Tangential Flow Update

    ByKilean January 31, 2016February 4, 2016

    Hey all! In this post, I’d like to present some of my final data on the exosome isolation project and cover some data that was generated in response to questions asked during our previous discussion. To begin with, Tom asked whether or not it was possible to measure protein in the filtrate and retentate and…

    Read More Exosome Isolation Using Tangential Flow UpdateContinue

  • NRG

    Journal Club: Two-Dimensional Porous Membrane

    ByJirachai January 26, 2016

    Presentation in this post is based on the paper entitled “Large Area Synthesis of a Nanoporous Two-Dimensional Polymer at the Air/Water Interface”. Paper: Murray(King)JACS15 Supporting Information: Murray(King)JACS15 – SI Presentation Slides (PDF): Two-Dimensional Porous Membranes    

    Read More Journal Club: Two-Dimensional Porous MembraneContinue

  • NRG

    Lift-Off Grant Update 01.12.16

    ByJosh Miller January 12, 2016

    160112 LO Grant Update

    Read More Lift-Off Grant Update 01.12.16Continue

  • NRG

    Slides for Jan 12th STTR Update

    ByTucker Burgin January 12, 2016

    01-12-16 NSF STTR Meeting Slides in .pptx format

    Read More Slides for Jan 12th STTR UpdateContinue

  • NRG

    Exosome Isolation Using Tangential Flow and Nanoporous Membranes

    ByKilean January 11, 2016February 11, 2019

    Hi all, I’m Kilean. I’m a first year grad student in BME doing my rotations. My rotation project has been working on developing a method that can isolate exosomes from blood plasma. We are trying to compete with techniques such as ultracentrifugation and ExoQuick, which are both the current preferred methods for isolating exosomes.  …

    Read More Exosome Isolation Using Tangential Flow and Nanoporous MembranesContinue

  • NRG

    Burst Pressure Tests of 75 nm HD chips (n=4)

    ByDean Johnson January 8, 2016January 12, 2016

    (UPDATED with n=4) I’ve repeated the burst pressure experiments performed by Sabrina, with the 75 nm thick hemodialysis chips. The previous chips are 50 nm with a burst pressure of 1.5 psi (10.5 kPa). I found the burst pressure of the 75 nm chips to be 3.62 psi (25 kPa) n=4. Increasing the thickness 1.5 x lead…

    Read More Burst Pressure Tests of 75 nm HD chips (n=4)Continue

  • NRG

    First Thoughts on ECMO

    ByTucker Burgin December 23, 2015January 30, 2016

    In preparation for the ICNMM conference next summer (and more immediately, the paper they’ve requested by January) I’ve started thinking about what our membranes can offer extracorporeal membrane oxygenation, or ECMO. This post will begin with some background information that I think is particularly important and progress into what work I’ve done so far on…

    Read More First Thoughts on ECMOContinue

  • NRG

    Nanomembrane transfer onto glass and SiN using vapor from tap and deionized water

    ByPedro Veiga December 19, 2015December 19, 2015

    Introduction: After meeting with Tucker, he showed me the experiment he conducted to induce membrane transfer to, supposedly, any kind of surface. The method he used was initially with breath, and then he passed on to deionized water vapor. The results were not satisfactory because of the wrinkles on the membrane and not much uniformity…

    Read More Nanomembrane transfer onto glass and SiN using vapor from tap and deionized waterContinue

Page navigation

Previous PagePrevious 1 … 71 72 73 74 75 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore