Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    Ibidi (Rev B) Device

    BySam Walker December 15, 2021January 19, 2022

    Introduction This post is meant to introduce the new NPN-enabled slide-based devices produced by Ibidi. These devices feature an NPN membrane and microfluidic channels positioned perpendicular to one another formed by PSA and COP layers (Figure 1). Channels above and below the membrane allow for flow-based experiments including tangential flow filtration (TFF) such that biofluids…

    Read More Ibidi (Rev B) DeviceContinue

  • NRG

    Seeing the Softer Side of Silicon: Polymer Coating Silicon Membranes Towards an in vitro Bacterial Infection Mimetic

    ByMichael Klaczko December 15, 2021March 5, 2024

    With our virus sensor paper now published, my journey with virus diagnostics, at least for now, comes to an end. Keeping with the theme of modifying silicon surfaces for interaction with pathogens, I am now switching gears to developing models for bacterial infection. This is currently taking shape in an effort to coat our silicon…

    Read More Seeing the Softer Side of Silicon: Polymer Coating Silicon Membranes Towards an in vitro Bacterial Infection MimeticContinue

  • NRG

    Comparison of Metrics to Quantify Fibrillar ECM Alignment

    ByAdeel Ahmed December 15, 2021December 15, 2021

    The physical properties of the extracellular matrix such as stiffness, viscoelasticity, fiber diameter, and chemical composition are well known as important modulators of cell behavior in vivo. Therefore, over the past decade, there has been a major emphasis on characterizing the properties of the in vivo ECM and also engineered matrices in vitro. In this context, properties such…

    Read More Comparison of Metrics to Quantify Fibrillar ECM AlignmentContinue

  • NRG

    A new idea to fabricate nano pocket membrane

    ByMunther Al-Sudais December 15, 2021December 15, 2021

      Starting in July of 2021, we began a new idea fabricating the nano pocket membrane to capture and release the EVs. From then until now we have successfully fabricated nano pocket membranes by using a lithography method. We faced challenges in parylene etching and resolve it by using two etching machines, i.e.  Trion Phantom…

    Read More A new idea to fabricate nano pocket membraneContinue

  • NRG

    Microfluidic control over millimeter scale alignment of collagen fibers

    ByAdeel Ahmed December 14, 2021December 15, 2021

    Type I collagen is a fibrous protein and the largest constituent of the ECM by mass. Collagen fibers are aligned across several millimeters to centimeters within load-bearing tissues, like the musculoskeletal tissue, cardiac tissue, and the cornea. Millimeter scale regions of fiber alignment are also observed in the tumor stroma and fibrotictissue. At the cell scale,…

    Read More Microfluidic control over millimeter scale alignment of collagen fibersContinue

  • NRG

    Affinity Based Capture of Streptavidin Conjugated EVs on the ALine

    ByMarlyn Torres December 14, 2021

    This post is a continuation of the affinity based capture of streptavidin conjugated EVs. The difference is that instead of using the tangential flow system we used the ALine devices. Sam’s previous work discussed the use of ALine devices for size based capture of EVs, but in this case we wanted to try the streptavidin-biotin…

    Read More Affinity Based Capture of Streptavidin Conjugated EVs on the ALineContinue

  • memBrains

    A Modular vascular barrier platform with a removable flow module and high resolution imaging (Publication draft)

    ByMehran Mansouri November 30, 2021November 30, 2021

    1. Introduction 1.1 Vascular barriers Functions: Maintain tissue homeostasis, control transport and gas exchange, recruit immune cells during inflammation Figure 1. Schematic illustration of a vasculature barrier in the human body. Endothelial cells as a building element of vasculature barriers line up along the vessel walls and separate the vessel from the tissue. Different stages…

    Read More A Modular vascular barrier platform with a removable flow module and high resolution imaging (Publication draft)Continue

  • memBrains | NRG

    Developing a Distributable µSiM ‘Transwell’-like Platform…Publication Figure Drafts

    ByMolly McCloskey November 28, 2021December 1, 2021

    Introduction Here, I will post figure drafts for the paper that introduces the modular µSiM (m-µSiM). Figures Remaining data to obtain: Occludin staining in IMR90-4 from UniBe in µSiM. We have tried this after 2 day culture in µSiM, which worked at UR but is not working at UniBe. Current problem: Occludin is not seen in…

    Read More Developing a Distributable µSiM ‘Transwell’-like Platform…Publication Figure DraftsContinue

  • NRG

    CRePE-ssNP UR Update Nov. 2021

    ByJim November 17, 2021

    To keep the NRG up-to-date on the goings-on in our collaboration with the University of Ottawa, we will plan to share our progress slide decks from the CRePE-ssNP group meetings that happen every two months. Periodically, we’ll also update the NRG on overall progress of the project including the work done in the two Ottawa…

    Read More CRePE-ssNP UR Update Nov. 2021Continue

  • memBrains

    R61: 12 Month Progress to NIH Slide Decks

    ByJim October 25, 2021October 25, 2021

    R61; 12 month Progress (Rochester) Small Trans-Agency Blood-Brain Interface Program Investigator Meeting – Agenda_FINAL

    Read More R61: 12 Month Progress to NIH Slide DecksContinue

Page navigation

Previous PagePrevious 1 … 20 21 22 23 24 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore