Skip to content

Nanomembrane Research Group

  • Home
  • Publications
  • MembranesExpand
    • Common Chip Formats
    • Common Membranes
    • Microslit Membranes
  • DevicesExpand
    • µSiMExpand
      • Geometry
      • µSiM CAD Files
      • AssemblyExpand
        • Protocols.io (µSiM Assembly)
        • Instructions
        • Common Issues and Troubleshooting Tips
      • Cell Culture ProtocolsExpand
        • Top Well: hCMEC/D3
        • Top Well: HUVEC
        • Bottom Channel Culturing
        • Immunocytochemistry Protocol
        • Impact of Chip Orientation on Fluorescence Imaging
        • Permeability: In Situ Method
        • Permeability: Sampling Method
        • Cell Culture Common Issues and Troubleshooting Tips
    • SepCon®Expand
      • Sepcon Assembly
      • Sepcon Video Protocol: Assembly
      • SepCon Gasket Silhouette File
      • SepCon Video Protocol: Wetting the membrane
      • SepCon Video Protocol: Disassembly
    • µSiM-DXExpand
      • µSIM Video Protocol: Capture of Nanoparticles
  • ImpactExpand
    • TraCe-bMPS
    • HCIC
    • LOMP
    • SiMPore
Nanomembrane Research Group
  • NRG

    Kilean’s Proposal Exam Documents

    ByKilean December 19, 2017

    Hi All, These are documents associated with my proposal: Silicon Nanomembranes for Rapid Liquid Biopsies from Whole Blood and Urine. Proposal: Kilean_Lucas_PhD_Thesis_Proposal_Reduced File Presentation: Proposal Presentation_03

    Read More Kilean’s Proposal Exam DocumentsContinue

  • NRG

    SEM images for Micro & Nano Scale experiments

    ByAslan December 18, 2017December 19, 2017

    Hello Everyone, I have been trying to take SEM images in 3 different steps during my experiments with polystyrene beads over Track Etched membranes including before capturing, After capturing and releasing. Micro Scale Experiments:  As you might remember, in Micro-scale experiments, we use 10 micron beads and 8 micron pores. Before capturing: This is only…

    Read More SEM images for Micro & Nano Scale experimentsContinue

  • NRG

    Dialysis Rotation Project

    ByLindsay Piraino December 16, 2017February 11, 2019

    Introduction Throughout my rotation, I have been working on the dialysis project with Alec. The goal was to set up a multi-pass system to analyze the membrane’s ability to separate different molecules in blood. The critical separation is between β2-microglobulin (12 kDa) and albumin (66 kDa) – β2-microglobulin is a large toxin that needs to…

    Read More Dialysis Rotation ProjectContinue

  • NRG

    Concentration VS Intensity in TE Experiments

    ByAslan December 4, 2017December 18, 2017

    Hello Everyone, Please note that Figures are all shown in the powerpoint file. The goal of these experiments was to plot a standard curve for concentration and intensity in my Track Etched Membranes. In order to that, we decided to dry droplets on the membranes with different dilution, then check the fluorescent intensity of them…

    Read More Concentration VS Intensity in TE ExperimentsContinue

  • NRG

    GO Hemocompatibility Study: I. Hemolysis

    ByHenry December 4, 2017December 12, 2017

    Intro Recently we have been collaborating with the Moghaddam lab from the University of Florida, which specializes in the fabrication of graphene oxide (GO) membrane, to study the use GO membrane as a toxin filter or absorbent in hemodialysis and live support devices. We are  responsible for the hemocompatibility component of the study and used the following…

    Read More GO Hemocompatibility Study: I. HemolysisContinue

  • NRG

    AFM Scans of NPN, MgF2, and Au-coated Membranes

    ByGreg Madejski December 1, 2017December 5, 2017

    With my TEM tilt stack work, we can see a marked difference in the roughness of npMg2 and NPN. Quantifying the bulk roughness properties of the npMgF2 using AFM gives us a way to check that property. Surface roughness has been known to effect SERS activity in other substrates, and our current hypothesis is that…

    Read More AFM Scans of NPN, MgF2, and Au-coated MembranesContinue

  • NRG

    Current Dialysis Research [McGrath Lab, December 2017]

    ByAlec November 27, 2017December 20, 2017

    Introduction The on going work for the dialysis project at UR has undergone changes and many hours of trouble shooting over the past semester. We are at a point now that I would like to share all the work I have done up until this point including assay development, method progression, and the experiments we…

    Read More Current Dialysis Research [McGrath Lab, December 2017]Continue

  • NRG

    UV-vis Spectrophotometer Measurements on NPN

    ByGreg Madejski November 22, 2017November 22, 2017

    We’d like to get verification of the absorption spectra of our npAu/npMgF2 SERS structure. The SERS effect should occur where the absorbance is maximized. Total Light = Absorbance + Reflection||Scattering + Transmittance Last Friday, I had the opportunity to work with Jennifer Kruschwitz who possesses a Konica-Minolta integrating sphere spectrophotometer from 380-740 nm (10 nm…

    Read More UV-vis Spectrophotometer Measurements on NPNContinue

  • NRG

    Study Proposal:In Vitro Cell Adhesion: Whole Blood, Single channel 5.4 mm chips

    ByDean Johnson November 16, 2017November 16, 2017

    The purpose of this study will be to compare the cellular adhesion on PEG vs Bare nano porous silicon nitride membranes using the same fluidic devices as the in vitro clearance study. The devices will need to be disassembled for imaging. Materials: 6 chips, 3 PEGylated, 3 Bare. gaskets for 6 devices Tygon tubing 2…

    Read More Study Proposal:In Vitro Cell Adhesion: Whole Blood, Single channel 5.4 mm chipsContinue

  • NRG

    Kidney Week 2017

    ByDean Johnson November 15, 2017

    I recently attended ASN’s Kidney Week 2017 in New Orleans. I mostly ate beans and rice, although there are three completely vegan restaurants and several restaurants with vegan options. The music was terrific and the weather was terrific, the people were terrific, etc. I had Five objectives for my trip to this conference. 1. Meet…

    Read More Kidney Week 2017Continue

Page navigation

Previous PagePrevious 1 … 46 47 48 49 50 … 231 Next PageNext

© 2026 Nanomembrane Research Group - WordPress Theme by Kadence WP

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Continue Shopping
    • Home
    • Publications
    • Membranes
      • Common Chip Formats
      • Common Membranes
      • Microslit Membranes
    • Devices
      • µSiM
        • Geometry
        • µSiM CAD Files
        • Assembly
          • Protocols.io (µSiM Assembly)
          • Instructions
          • Common Issues and Troubleshooting Tips
        • Cell Culture Protocols
          • Top Well: hCMEC/D3
          • Top Well: HUVEC
          • Bottom Channel Culturing
          • Immunocytochemistry Protocol
          • Impact of Chip Orientation on Fluorescence Imaging
          • Permeability: In Situ Method
          • Permeability: Sampling Method
          • Cell Culture Common Issues and Troubleshooting Tips
      • SepCon®
        • Sepcon Assembly
        • Sepcon Video Protocol: Assembly
        • SepCon Gasket Silhouette File
        • SepCon Video Protocol: Wetting the membrane
        • SepCon Video Protocol: Disassembly
      • µSiM-DX
        • µSIM Video Protocol: Capture of Nanoparticles
    • Impact
      • TraCe-bMPS
      • HCIC
      • LOMP
      • SiMPore